Clean dental evacuation lines lead to more air flow from the dental vacuum allowing aerosols to be efficiently mitigated. Using a proper solution and engineering device is critical in creating a safer dental visit.

Daily cleaning of evacuation lines

Every dental facility needs to clean evacuation lines at the end of each clinical day to remove debris build-up and ensure proper suction flow. Cleaning can be done more often if deemed necessary due to the procedure such as after extractions, periodontal therapy, or the removal of sticky resin restorations.


 
Use a cleaner with a pH between 6 – 8 

Use a cleaning solution that meets the EPA’s criteria of a pH between 6-8 when diluted and mix it according to the solution’s Instructions for Use (IFU). 

 

Don’t use bleach

The EPA’s final rule for dental amalgam waste prohibits the use of bleach or chlorine-containing cleaners that may lead to the dissolution of solid mercury when cleaning chair-side traps and 
vacuum lines.

 

Use a non-foaming cleaner

The use of a non-foaming cleaner is recommended, especially for use with dry vacuums, as foam cleaners tend to leave the turbine coated with residue and debris, leading to lower performance, loss of suction and eventual pump failure.

 

Monarch CleanStream Evacuation Line Cleaning Solution

monarch-evacuation-line-cleaning-solution

  • Unique formulation removes and prevents debris build-up in evacuation lines 
  • maintaining peak performance of vacuum flow and suction. 
  • Cleans and deodorizes evacuation lines for all wet and dry vacuum systems. Non-foaming. 
  • Highly concentrated formula is very economical and 1 bottle yields 125 uses. 
  • Amalgam separator compatible with a pH of 7-8. 
  • Non-corrosive, for daily use.
  • Safe for clinicians and others who may be exposed to the cleaning liquid.
  • Liquid is effective for 5 days if pre-mixed.

Use an engineering device 

Use an engineering device that has been proven to create a vortex that can clean the full 360° area of evacuation lines and plumbing.

 

Monarch CleanStream Dispenser with Vortex Technology

monarch-cleanstream-dispenser-dental-evacuation-system

  • Creates a vortex of the cleaning solution ensuring a full 360° coverage of evacuation lines resulting in improved suction performance.
  • Standardizes the process for maximum efficiency.
  • Atomizes the correct amount of solution automatically so you don’t use too much or too little.
  • Cleans up to 2 HVEs and 1 SE simultaneously hands-free optimizing clinician efficiency.
  • One dispenser can clean up to two operatories.
  • Recommendation: Have at least 1 dispenser for every 2 operatories and ideally have one for each operatory.

 

Watch the CleanStream Vortex Dispenser in action by clicking here

 

Follow a standard cleaning procedure 

The ideal end of the day cleaning process starts with cleaning the room that is the furthest away from the mechanical room and moving closer to the mechanical room. This prevents lines from being re-contaminated. 

dental-practice-office-layout

Weekly change of chair side traps 

Disposable suction traps should be changed weekly or more often if they 
become clogged. Before cleaning or changing the trap, it is best to run some 
evacuation cleaner down the line, followed by water. 

 

Monthly change of the wet vacuum’s solids collector 

Replace the Intake Solids Collector monthly (or as needed) to ensure peak 
performance of your equipment. 